Mahape, Mumbai, Maharashtra
GST No. 27AABCC2221M1ZV
Call 08046046436 75% Response Rate
Product Brochure
Brand | Chino |
Model No. | KP2000 Series |
DIN Size | 96 x 96 mm |
Controller Function Type | Proportional |
Control output Type | Relay, Analog (mA/mV), SSR |
Voltage | 100-240 V |
Compatible Thermocouples | B,R,S,K,E,J,T,N,L,WRe5-WRe26,W-WRe26,NiMo-Ni,CR-AuFe,PR5-20,PtRh40-PtRh20,Platinel II,U |
Input Type | Universal |
Working Temperature Range | -10 to 50 Degree C |
Working Humidity Range | 10 to 90% RH |
Weight | Without options Approx. 450g |
Input type | Thermocouple: B, R, S, K, E, J, T, N, WRe5-WRe26, W-WRe26, NiMo-Ni, CR-AuFe, PR5-20, PtRh40-PtRh20, Platinel II, U, L DC voltage: ±10mV, ±20mV, ±50mV, ±100mV, ±5V, ±10V DC current: 0 to 20mA Resistance thermometer: Pt100, JPt100, Old Pt100, JPt50, Pt-Co |
Accuracy rating | ±0.1% of measuring range ± 1 digit *For details, refer to [Detailed specifications of accuracy ratings]. |
Reference temperature compensation accuracy | K, E, J, T, N, Platinel II --- ±0.5°C or a value equivalent to ±20µV, whichever is greater (at ambient temperature of 23°C ± 10°C) Others --- ±1.0°C or a value equivalent to ±40µV, whichever is greater |
Sampling period | Approx. 0.1 seconds |
Displays element | Upper display LED Lower display LCD (with back light) 108 x 24 dots |
Display content | Upper display: PV 5-digit, SV 5-digit, status indications, etc. Lower display: MV, output status, setting screens, etc. |
Control cycle | Approx. 0.1 seconds |
Output type | ON-OFF pulse type, ON-OFF servo type, Current output type, SSR drive pulse type, Voltage output type |
Number of patterns | 30 patterns Pattern repetition ... Maximum 9999 times |
Number of steps | 19 steps/pattern Step repetition ... Maximum 99 times |
Control relations | PID 8 types P : 0 to 999.9% I : 1 to 9999 seconds D : 0 to 9999 seconds A.R.W. (Anti reset windup) High limit --- 0 to 100.0% Low limit --- -100 to 0.0% |
Number of alarm points | 4 points |
Alarm types | Absolute value alarm, deviation alarm |
Output signal | Relay output signal (a contact) |
View Complete details
Product Brochure
Weight | Terminal block type: 150g |
Input Signal | Group selection by the models (Thermocouple, Resistance Thermometer, DC voltage/current) |
Socket Type | 200g (including socket) |
Range Type | Refer to a measuring range table |
Input Sampling Cycle | 500ms |
Accuracy Rating | +-0.5%FS+-1digit |
ON OFF pulse output type | 1c 250V AC, 30V DC 3A (resistance load) |
Current output type | 0 to 20 A DC, 4 to 20 mA DC (It can be changed by the setting) |
SSR drive pulse output type | 19V DC+-15%, Internal resistance 82, Allowable current Max. 24mA DC |
Operation Temperature | 0 to 50degC |
Structure | IP66 (front part) |
View Complete details
Product Brochure
Usage/Application | Industrial |
Type | Automatic |
Weight | LT35A 250g, LT37A 300g |
Brand | CHINO |
DC Power Supply | 24 V AC, 50/60Hz/24V DC |
Accuracy Rating | +- 0.2%FS +- 1digi |
View Complete details
Product Brochure
Usage/Application | Industrial |
Type | Automatic |
Weight | Without options Approx. 450g |
Brand | Chino |
Working Temperature Range | -10 to 50degC |
Working Humidity Range | 10 to 90%RH |
Color | Gray or Black |
External Dimensions | 96 (H) x 96 (W) x 127 (D) *The depth from the front panel is 120mm |
Input type | ThermocoupleB, R, S, K, E, J, T, N, WRe5-WRe26, W-WRe26, NiMo-Ni, CR-AuFe, PR5-20, PtRh40-PtRh20, Platinel II, U, L DC voltage ±10mV, ±20mV, ±50mV, ±100mV, ±5V, ±10V DC current0 to 20mA Resistance thermometerPt100, JPt100, Old Pt100, JPt50, Pt-Co |
Accuracy rating | ±0.1% of measuring range ± 1 digit *For details, refer to [Detailed specifications of accuracy ratings]. |
Reference temperature compensation accuracy | K, E, J, T, N, Platinel II --- ±0.5°C or a value equivalent to ±20µV, whichever is greater (at ambient temperature of 23°C ± 10°C) Others --- ±1.0°C or a value equivalent to ±40µV, whichever is greater |
Sampling period | Approx. 0.1 seconds |
Displays element | Upper display LED Lower display LCD (with back light) 108 x 24 dots |
Display content | Upper display: PV 5-digit, SV 5-digit, status indications, etc. Lower display: MV, output status, setting screens, etc. |
Control cycle | Approx. 0.1 seconds |
Output type | ON-OFF pulse type, ON-OFF servo type, Current output type, SSR drive pulse type, Voltage output type |
SV relations | SV 8 types (maximum 5 digits setting) SV range SV rate-of-change |
Control relations | PID 8 types P : 0 to 999.9% I : 1 to 9999 seconds D : 0 to 9999 seconds A.R.W. (Anti reset windup) High limit --- 0 to 100.0% Low limit --- -100 to 0.0% |
Number of alarm points | 4 points |
Alarm types | Absolute value alarm, deviation alarm, absolute value deviation alarm, setting value alarm, output value alarm, control loop abnormality alarm, FAIL, timer |
Output signal | Relay output signal (a contact) |
Rated power voltage | General power supply specifications 100 to 240VAC 24V power supply specifications 24VAC/24VDC |
Rated power supply frequency | General power supply specifications 50/60Hz 24V power supply specification 50/60Hz (24VAC) |
View Complete details
Product Brochure
Input Signal | Universal input (Thermocouple, Resistance Thermometer, DC voltage/current) |
Range Type | Refer to a measuring range table |
Input Sampling Cycle | 100 ms |
Accuracy Rating | +- 0.1%FS +- 1digi |
Reference Junction Compensation Accuracy | +- 0.5degC (at ambient temperature 23degC +- 2degC) |
Output Point | Max. 3 points |
Contact Capacity | 250V AC/ 30V DC 2A (resistance load) |
Ambient Temperature Range | 0 to 50 degC |
Output type | ON-OFF pulse output type 1c 250V AC/ 30V DC 3A (resistance load)ON-OFF servo output type 1a 250V AC 8A(resistance load), FB resistance: 100 to 2500ΩCurrent output type 0 to 20mA DC, 4 to 20 mA DC (It can be changed by the setting)Voltage output type 1 to 5V, 0 to 5V, 0 to 10V (It can be changed by the setting)SSR drive pulse output type 19V DC±15%, Internal resistance 82Ω, Allowable current Max. 24mA DC |
Type | Absolute value, deviation, loop diagnosis, timer, heater disconnection and etc. Total 33 types*Event output is a standard feature. |
Power supply voltage range | AC power supply: 100 to 240 V AC, 50/60HzDC |
Power supply | 24 V AC, 50/60Hz/24V DC |
Power consumption | AC power supply: 12 VA and/or lower |
DC power supply | 12 VA and/or lower (24V AC) 8W and/or lower (24V DC) |
Safety standards | CE marking compliant product |
View Complete details
Product Brochure
Usage/Application | Industrial |
Type | Automatic |
Thermocouple | +- 10V or less |
Brand | CHINO |
DC Current | +- 30mA or less, +- 7.5V or less |
Common Mode Rejection Ratio | 130dB or more (50/60Hz) |
Input type | Input range | Rating accuracy | Exceptionally Specified Accuracy |
B | 0 to 1820 °C | ±0.25%±1digit However, more than 200°C or less than 0°C is ±0.5%±1digi | 0 to 400°C: Out of specifications 400 to 800° C: ±0.5%±1digit |
R | 0 to 1760° C | 0 to 400°C:±0.5%±1digit | |
S | 0 to 1760° C | 0 to 400° C:±0.5%±1digit | |
K1 | -200 to 1370°C | - | |
K2 | -199.9 to 500.0°C | - | |
E | -199.9 to 700.0°C | - | |
J | -199.9 to 900.0°C | - | |
T | -199.9 to 400.0°C | - | |
U | -199.9 to 400.0°C | - | |
L | -199.9 to 900.0°C | - | |
WRe5-WRe26 | 0 to 2310°C | - | |
W-WRe26 | 0 to 2310°C | 0 to 400°C:±0.5%±1digit | |
PtRh40-PtRh20 | 0 to 1880° C | 0 to 400°C: Out of specifications 400 to 800 °C:±1.5%±1digit | |
Platinel II | 0 to 1390°C | - | - |
Pt100 1 | -199.9 to 850.0°C | ±0.25% ±1digit | - |
Pt100 2 | -199.9 to 200.0°C | - | |
JPt100 1 | -199.9 to 649.0°C | - | |
JPt100 1 | -199.9 to 200.0°C | - | |
5V | 0 to 5V (0.000 to 5.000) | ±0.25% ±1digit | - |
20mA* | 4 to 20mA (equivalent to 1.00 to 5.00 V) | *DC voltage with 5 V is used. *Except for shunt resistor accuracy. |
View Complete details
Model No. | LT23A |
Size | 48 x 48 mm |
Control Type | PID/On-Off |
Brand | CHINO |
Display Type | 4 Digit/7 Segment |
Frequency | 50 Hz |
Construction | IP 66 |
Accuracy | +- 0.5% |
Easy to use small sized controller in cost performance. Compact size with plenty of control function. LT23A is compact size of 48x48 mm with depth of 60mm. Socket type is also available and it can correspond various installation such as panel installation and rail type installation as well. The front size of LT23A digital controller is a dust proof and drip proof protaction structure for IP66.
In addition to the conventional PID method, high performance type PID using an algorithm aimed at converting hunting more quickly and shortening setting time is also carried.
Features
Additional Information:
View Complete details
Mounting Type | Surface Mounting |
Output type | Relay |
Brand | CHINO |
Control Type | Proportional |
Sensor Input | RTD |
Accuracy | 0.1 |
Display Type | Digital |
Voltage | 120 - 180 V |
Various functions and high precision advanced model. More ever, by overshoot suppression function which suppresses overshoot at SP change and disturbance response, it makes it possible to control more reliable against disturbance and stability.
Features
Additional Information:
View Complete details
Type | Automatic |
Brand | CHINO |
Alarm | 4 points |
Display Type | Digital |
Number Of Functions | 8 |
Voltage | 120 - 180 V |
DB Series are digital indicating controller with indicator accuracy of 0.1% along with control period about 0.1 second. 96x96 mm, Multi setting function (8 types), multi range input function and various other function as standard equipment.
Features:
Additional Information:
View Complete details
Model No. | DB650 |
Control Type | On-Off |
Brand | Chino |
Accuracy | +- 0.1% |
Display Type | 4 Digit/7 Segment |
Voltage | 120 VAC |
View Complete details
Power Supply | 100 to 240VAC, 50/60Hz (universal power supply) |
Power Consumption | Maximum 15VA |
Weight | About 330g |
Measuring Current | 2mA +- 20% |
Ambient Humidity | 20 to 90%RH (no dew condensation) |
Ambient Temperature | -10degC to 50degC |
Digital Filter | 0.0 to 99.9 seconds |
Measuring Input Shift | -199.9 to 999.9 times of setting resolution |
Sampling Period | About 0.2 second |
Measuring Unit | degC or degF (by internal switch) |
Accuracy Rating | +-0.3% of measuring range +- 1 digit |
Input signals | Measuring ranges (Resolution) | |
Thermocouples | R | 0 to 1760°C (0.1°C) |
S | 0 to 1760°C (0.1°C) | |
B | 0 to 1820°C (0.1°C) | |
K | -200 to 1370°C (0.1°C) | |
-200 to 500°C (0.1°C) | ||
E | -270 to 700°C (0.1°C) | |
J | -200 to 900°C (0.1°C) | |
T | -200 to 400°C (0.1°C) | |
N | 0 to 1300°C (0.1°C) | |
U | -200 to 400°C (0.1°C) | |
L | -200 to 900°C (0.1°C) | |
DC voltage* | -20 to 20mV, -5 to 5V | |
DC current* | 0 to 20mA | |
Resistance thermometers | Pt100 | -200 to 660°C (0.1°C) |
-200 to 200°C (0.1°C) | ||
JPt100 | -200 to 649°C (0.1°C) | |
-200 to 200°C (0.1°C) | ||
Pt50 | -200 to 649°C (0.1°C) |
Input signals | Thermocouples | B, R, S, K, E, J, T, U, L |
DC voltage | ±20mV, ±5V | |
DC current | 0 to 20mA | |
Resistance thermometers | Pt100, JPt100, Pt50 | |
Burnout | Upscale burnout for thermocouple, mV and resistance thermometer inputs | |
Scaling decimal point | Optional setting from "without decimal point" to 4 digits | |
Display | Measured value … 7-segment LED 4-1/2 digits Alarm value … Indication by 2 independent LED lamps | |
Power interruption countermeasure | Setting parameters are retained more than 10 years. | |
Case material | ABS resin | |
Installation | Panel |
View Complete details
Product Brochure
Brand | CHINO |
Model No. | DB600 Series |
Input Type | RTD, Voltage (mV), Thermocouple |
Accuracy | +-1% |
Voltage | 100 VAC |
Frequency | 50/60Hz |
Input type: | Thermocouple B, R, S, N, K, E, J, T, U, L, WRe5-WRe26, W-WRe26, Platinel II, PtRh4--PtRh20, Au-Pt DC Voltage ±20mV, ±100mV, ±5V, ±10V Resistance thermometer Pt100, JPt100, Pt50 |
Measuring Range: | Thermocouple 16ranges, DC voltage 4ranges, Resistance thermometer 5ranges |
Temperature unit: | °C |
Accuracy rating: | ±0.1% of FS ±1 digit of measuring range, For details, refer to "measuring ranges and accuracy ratings" in PS sheet |
Reference junction compensation accuracy: | ±1.0°C (ambient temperature 23°C ± 10°C) ±2.0°C (temperature other than above) |
Sampling rate: | Approx. 0.1 seconds |
Burnout: | Upper limit burnout is provided for thermocouple, resistance thermometer and DC voltage (20mA) only as standard. Output 1 produces PV abnormal output and output 2 is fixed to 0% when burnout occurs. Upper limit alarm event is output. |
Input impedance: | Thermocouple 1MΩ or more DC voltage Approx. 1MΩ |
View Complete details
Product Brochure
Model Name/Number | CT230 Series |
Display Type | Digital |
Weight | About 120g |
Brand | Chino |
Measuring Unit | Degree C or F |
Sampling Cycle | About 0.5 second |
Power Consumption | About 7 V |
Ambient Temperature | 0 to 50 Degree C |
Ambient Humidity | 35 to 85%RH (No dew condensation) |
Voltage | 100-240 V |
DIN Size | 48 x 48 mm |
Inputs | Input ranges | ||
Thermocouple | K | -200 to 1370°C | -300 to 2450°F |
J | -199.9 to 900.0°C | -300 to 1650°F | |
Resistance thermometers | Pt100 | -199.9 to 850.0°C | -300 to 1500°F |
Thermocouple | R | 0.0 to 1760°C | 32 to 3200°F |
S | 0.0 to 1760°C | 32 to 3200°F | |
T | -199.9 to 400.0°C | -300 to 700°F |
Input signal | Thermocouple K, J, R, S, T |
Accuracy rating | Thermocouple: Within ±0.3% of each input span ± 1 digit Less than 0°C(32°F): Within ±0.4% of each input span ±1 digit However, R & S inputs, 0 to 200°C(0 to 400°F) within ±8°C(16°F) |
Dielectric strength | Between input terminal and power terminal: 1.5kVAC for 1 minute Between output terminal and power terminal: 1.5kVAC for 1 minute |
Event output | Relay contact: 1a Control capacity: 3A 250V AC (resistive load) Electrical life: 100,000cycle |
Drip proof/Dust proof | IP65 for front panel |
View Complete details